Critical Service
Engineered for applications where chemical injection cannot be interrupted, delivering continuous, precise flow even under challenging field conditions. Built with multiple levels of redundancy, each system is designed to detect anomalies, trigger alarms, and automatically switch to backup hardware without interrupting injection, ensuring operations continue uninterrupted while field staff respond.
- Overview
- Resources
Features
- Continuous operation with redundant pump options
- Automatic flow compensation for precise injection
- Closed-loop feedback to optimize chemical use
Design Specifications
LEVEL 1
Two pumps are connected to a single controller, and both operate simultaneously. If one pump loses efficiency as noted by the InSight Smart Sight Glass, both motors increase rpm to compensate.
LEVEL 2
Two pumps are connected to a single controller, each using an independent InSight Smart Sight Glass. Only one pump runs at a time. If the operating pump's efficiency falls out of specification that pump stops and the redundant pump starts.
LEVEL 3
Two pumps are tied into two controllers each with its own InSight. Only one pump runs at a time. If the operating pump's efficiency falls out of specification that system stops and the second system starts